Pump Protection Relay – DPP3

$54.63

Advance pump protection relay to safeguard against damage to borehole pumps. The unit is easily calibrated and then monitors all important pump characteristics. All parameters are saved in non-volatile memory to be available even after power loss. A re-start delay ensures the borehole replenishing before pumping starts again.

 

Features:

 

  • High resolution analogue microprocessor
  • High current sensing input (up to 15A)
  • Automatic diagnosis of pump
  • Fixed start-up delay (10 sec)
  • Front face calibration / reset button
  • Monitors over and under current
  • Three retries for over current
  • Under current ( dry running ) restart delay
  • Monitors over and under voltage
  • Security input to control pump
  • Modular 35.5mm DIN rail mountable
  • High current 16A SPST output relay
  • LED indication for faults
  • LED indication for power supply ON
Clear selection

Description

Input Specifications

Current Input Pin 7 & 9
Measuring Ranges 1 – 15 A
Over current limit 12%
17% extended
Recovery Time 15 sec
(3 attempts then permanent OFF)
Under current limit 8%
12%
Recovery Time 2hrs
Maximum Overload current 20 A (30 sec)
Voltage Input Pin1, 5
Measuring Range 180 – 260 VAC DPP1
Over / Under voltage limit ≤15%
≤20% (extended)
Hysteresis 5%

Output Specifications

Output Specifications SPDT
Rated Isolation Voltage 6000 VAC (contact / electric)
1000 VAC (contact / contact)
Nominal Rate in AC1 (AG-Ni) 4000 VA
Rated Current 16A
Rated Voltage 250V
Mechanical Life 10×106 cycles
Electrical Life 10×103 cycles (at max load)
Operation Frequency ≤ 1800 cycles/h

Supply Specifications

Power Suppy AC Type 110, 230, 400V ± 10%
(Galvanic) 50 / 60 Hz ± 5%
Galvanic Isolation 4kV
Consumption ± 3VA
±6 VA 525 VA

General Specifications

Power ON Delay ≤ 300 ms
Power OFF Dela ≤ 200 ms
Indication for
Power Supply ON LED green
Status LED yellow
Output ON LED red
Environment
Degree Of protection IP 20
Operating Temperature -10 to + 50°C
Storage Temperature -50 to + 85°C
Weight 200g

Additional information

Supply Voltage

525Vac, 400Vac, 230Vac, 110Vac

Reviews

There are no reviews yet.

Be the first to review “Pump Protection Relay – DPP3”